Mon–Fri 08:00–20:00 | Sat 09:00–14:00
Authorised Repair Service

Ariston Repair Service

Professional Ariston appliance repairs at your home. Certified technicians, genuine Ariston spare parts and a written warranty on every job.

Ariston Appliance Repair Service

Specialist repairs using genuine Ariston spare parts

Ariston tumble dryer repair in Solihull
Ariston Tumble DryerRepair in Solihull
Most Requested

Laundry

Certified repair for Ariston tumble dryer. Drum, motor and control board faults resolved at home with genuine spare parts.

Washing machine not draining?

Most Ariston laundry faults are repaired in a single visit. Get a free, no-obligation quote today.

Call Now: 808 502 0600
Ariston fridge repair in Solihull
Ariston FridgeRepair in Solihull
Ariston freezer repair in Solihull
Ariston FreezerRepair in Solihull
Urgent Response

Cooling

Same-day response for urgent Ariston fridge and freezer breakdowns. Compressor, thermostat and sealed system repairs across West Midlands.

Fridge not cooling? Every minute counts.

Emergency Ariston cooling repairs available today. Call now to save your food.

Book a Repair: 808 502 0600
Ariston cooker repair in Solihull
Ariston CookerRepair in Solihull
Ariston hob repair in Solihull
Ariston HobRepair in Solihull
Kitchen Specialists

Cooking

Expert diagnostics for all Ariston cooker and hob. Heating elements, thermostats, igniters and control boards repaired on site.

Oven not heating evenly?

Certified Ariston kitchen engineers across Solihull. Book a repair and get cooking again.

Contact Us
Ariston dishwasher repair in Solihull
Ariston DishwasherRepair in Solihull
Clean Kitchen

Cleaning & Extraction

Ariston dishwasher repairs. Pump, spray arm, drainage and motor faults fixed at your home with genuine parts.

Dishwasher showing an error code?

No call-out charge when the repair goes ahead. Genuine Ariston parts and a written warranty included.

Book a Visit: 808 502 0600
Ariston boiler repair in Solihull
Ariston BoilerRepair in Solihull
Ariston water heater repair in Solihull
Ariston Water HeaterRepair in Solihull
Gas Safe Registered

Heating

Gas Safe registered engineers for Ariston boiler and water heater. Fault diagnosis, part replacement and annual servicing across West Midlands.

No hot water or heating?

Ariston heating breakdowns repaired fast by Gas Safe engineers. Available seven days a week across West Midlands.

Call Now: 808 502 0600
Ariston air conditioning repair in Solihull
Ariston Air ConditioningRepair in Solihull
Certified Engineers

Climate Control

F-Gas certified engineers for Ariston air conditioning. Installation, fault diagnosis and refrigerant handling across West Midlands.

Air conditioning not cooling?

Ariston climate control repairs by certified engineers. Same-day response available across West Midlands.

Contact Us
Ariston heat pump repair in Solihull
Ariston Heat PumpRepair in Solihull
Green Technology

Renewable Energy

MCS-accredited installation and repair for Ariston heat pump. Heat pump diagnostics, refrigerant handling and efficiency optimisation.

Heat pump underperforming?

Specialist Ariston renewable energy engineers. MCS-accredited service across West Midlands.

Speak to an Engineer: 808 502 0600
Ariston wine cooler repair in Solihull
Ariston Wine CoolerRepair in Solihull
Premium Service

Premium Appliances

Specialist repairs for Ariston wine cooler. Precision components and brand-specific diagnostics for high-end appliances.

Premium appliance? Premium service.

Specialist Ariston premium appliance repairs. Treated with the care your appliance deserves.

Book a Visit: 808 502 0600

Why Ariston Appliances Need Specialist Repair

Ariston appliances incorporate advanced proprietary systems that require certified engineers with brand-specific training to diagnose and repair correctly.

Diagnostic Systems

Ariston appliances use integrated electronic diagnostics. Our engineers connect directly to Ariston control boards using brand-specific tools to read fault codes and pinpoint issues accurately.

Genuine Parts

Every repair uses genuine Ariston spare parts sourced directly from authorised distributors. Original components ensure compatibility, performance and longevity — backed by a manufacturer warranty.

Safety Standards

Ariston appliances must meet strict UK safety regulations. Our certified engineers follow Ariston service procedures and test every repair to BS EN standards before sign-off.

Smart Connectivity

Many Ariston appliances feature Wi-Fi connectivity and smart home integration. Our engineers can diagnose firmware issues, reset connectivity modules and restore remote control functionality.

Common Ariston Error Codes

What does error code 2P8 mean on an Ariston heat pump?

Error code 2P8 on an Ariston heat pump indicates a low pressure warning in the heating circuit. Check the system pressure gauge and repressurise using the filling loop if below 1.0 bar. If pressure keeps dropping, contact a qualified heat pump installer to check for leaks.

What does error code 504 mean on an Ariston boiler?

Error code 504 on an Ariston boiler indicates flame lift - the flame has separated from the burner or been cut off during operation. This is a gas-related fault. Do not attempt to fix this yourself. If you smell gas, do not operate any switches, ventilate the area if safe to do so, leave the property and call the Gas Emergency line from outside. If there is no gas smell, switch off the boiler and contact a Gas Safe registered engineer.

What does error code 610 mean on an Ariston boiler?

Error code 610 on an Ariston boiler indicates the thermal fuse has opened due to excessive heat. This is a combustion safety device. Do not use the boiler. If you smell gas or fumes, do not operate any switches, ventilate the area if safe to do so, leave the property and call the Gas Emergency line from outside. Contact a Gas Safe registered engineer to investigate the cause.

What does error code 304 mean on an Ariston boiler?

Error code 304 on an Ariston boiler indicates the boiler has been reset more than 5 times in 15 minutes. Switch off completely and wait at least 15 minutes before switching back on. Contact a Gas Safe registered engineer to diagnose the underlying problem causing repeated faults.

What does error code 103 mean on an Ariston boiler?

Error code 103 on an Ariston boiler indicates insufficient circulation - the water is heating too quickly. Switch off the boiler and check all radiator valves are open. Bleed any airlocks from the system. If the problem persists, contact a Gas Safe registered engineer.

Frequently Asked Questions

How do I drain my Ariston unvented cylinder?

Switch off electrical power to the cylinder. Turn off the cold water supply and close the hot water outlet valve. Connect a hose to the drain cock at the bottom of the cylinder and place the other end in a suitable drain or basin. Open the drain cock and then open the temperature and pressure relief valve to allow air into the cylinder and enable draining.

What is the anti-legionella function on my Ariston water heater?

The anti-legionella function is a thermal disinfection cycle that periodically heats water to a high temperature to kill legionella bacteria. This function is activated by default on Ariston water heaters and runs automatically to protect your health. Do not disable this function. Consult your product manual for specific temperature and duration settings for your model.

What should I do if I have hard water with my Ariston heat pump?

Where the mains total water hardness exceeds 200 ppm, provision should be made to treat the feed water to reduce the rate of limescale accumulation.

Why is my Ariston water heater leaking from the bottom?

Leaking from the bottom of the unit suggests a faulty or damaged heating element. Scale buildup on the heating element can cause this problem. Switch off the water heater at the electrical supply immediately and turn off the water supply to the unit. Water and electricity are a dangerous combination. Contact a qualified technician for inspection and repair.

What does error code 501 mean on my Ariston boiler?

Error code 501 indicates your boiler has failed to ignite. This can be caused by gas supply interruptions, blocked burner jets, or faulty ignition components. This is a gas-related fault. Do not attempt to fix this yourself. If you smell gas, do not operate any switches, ventilate the area if safe to do so, leave the property and call the Gas Emergency line (0800 111 999) from outside. Contact a Gas Safe registered engineer for repairs.

Book a Ariston Repair

Specialist Ariston engineers. No-obligation quote.

Call Now: 808 502 0600